A05 Enhanced Air Quality (WELL v2, Q2 2025)
Concept: Air · Type: Optimization · Maximum points: 4
Intent
Encourage and recognize buildings with enhanced levels of indoor air quality that promote the health and well-being of people.
Summary
This WELL feature requires projects to go beyond current guidelines to provide enhanced air quality levels that have been linked to improved human health and performance.1,2
Issue
The quality of the air people breathe indoors directly impacts their health and well-being and constitutes one of the most important aspects of buildings that can support human health. Researchers have also identified a clear relationship between indoor air quality and human productivity in buildings.3 An average of 10% of productivity loss could be attributable to health issues related to poor indoor air quality in office buildings.4 There is also an emerging body of evidence that air pollution can disrupt physical and cognitive development in children.5 Studies have also shown that air pollution contributes to the large global burden of respiratory and allergic diseases, as well as the premature deaths of adults and children.6 The premature mortality rate could be reduced by up to 15%, if PM10 is reduced from 70 to 20 µg/m3.7 As a result, enhanced air quality is positively correlated with improved health, cognitive and physical development, higher incomes and better economic performance.1,2Evidence
Indoor air quality can be properly managed primarily through source control strategies, passive and active building design and operation strategies and human behavior intervention. High levels of indoor air quality require both professionals and building users to collaborate in the implementation of adequate approaches.
Requirements
A05.1 Meet Enhanced Thresholds for Particulate Matter — 1–2 points (max 2)
Applies to: All Spaces.
The following requirement is met:
Projects comply with the thresholds specified in the table below:
Tier Particulate Matter Thresholds Points 1 PM2.5: 12 µg/m³ or lower.8
PM10: 30 µg/m³ or lower.9
1 2 PM2.5: 10 µg/m³ or lower.9
PM10: 20 µg/m³ or lower.9
2
Verification: Performance Test OR Sensor Data
Performance verification: PM2.5 and PM10
Test method:
- Measurement method: real-time direct reading instrument.
- Duration of measurement: minimum of one continuous hour (10 minutes of acclimation time followed by 50 minutes of measurement time), with measurements recorded at least once every minute.
Device requirements:
- Instrument type: light-scattering airborne particle counter
- Measurement range: 1-1,000 μg/m3
- Instrument accuracy (at the size specified by the manufacturer): ≤ 15%
- On-screen resolution: 1 μg/m3
- Lower detectable limit: 1 μg/m3
- Reporting interval: one minute maximum
- Calibration: instrument must be calibrated within the manufacturer’s specification (maximum interval: one year), and the calibration record (i.e., the measurement result obtained during calibration) must be traceable in NIST.
Reporting and compliance:
- Compliance is based on the median value collected during the measurement time at each sampling point compared against the requirement in WELL + a tolerance of 20%.
Refer to the Performance Verification Guidebook for information on sensor/testing requirements, required testing duration and compliance calculations.
WELL Core:
Meet these requirements in the whole building. Achievement requires access to at least 10% of leased space for testing as identified by the project.A05.2 Meet Enhanced Thresholds for Organic Gases — 1 point
Applies to: All Spaces.
The following thresholds are met in occupiable spaces:
Acetaldehyde: 140 µg/m³ or lower.10
One of the following:
- Acrylonitrile: 5 µg/m³ or lower.10
- Caprolactam: 2.2 µg/m³ or lower.10
Benzene: 3 µg/m³ or lower.10
Formaldehyde: 9 µg/m³ or lower.10
Naphthalene: 9 µg/m³ or lower.10
Toluene: 300 µg/m³ or lower.10
Verification: Performance Test
Performance verification: Formaldehyde
Test method:
- Samples are taken through an active collection in accordance with ISO 16000-3, ASTM D5197, NIOSH 2016, EPA TO-11 (or 11A) or EPA Compendium Method IP-6 (or 6A).
- Minimum of one continuous hour OR the duration of sampling volume prescribed by the referenced testing methodology.
- A minimum of one exposure field blank sample must be prepared and analyzed per day of sampling.
Device requirements:
- Laboratory materials and/or samplers must be prepared according to the referenced testing methodology and meet the referenced testing methodology requirements.
- Air sampling pumps utilized in active collection measurements must be capable of meeting the airflow rates prescribed by the referenced testing methodology (if applicable).
Reporting and compliance:
- Compliance is based on the measured concentration at each location compared against the requirement in WELL + tolerance of 20%.
Performance verification: VOCs (except Formaldehyde)
Test method:
- Samples are taken through an active collection in accordance with ISO 16000-6, ASTM D5197 or EPA TO-17.
- A minimum of one exposure field blank sample per day of sampling must be prepared and analyzed.
Device requirements:
- Laboratory materials and/or samplers must be prepared according to the referenced testing methodology and meet the referenced testing methodology requirements.
- Air sampling pumps utilized in active collection measurements must be capable of meeting the airflow rates prescribed by the referenced testing methodology (if applicable).
Reporting and compliance:
- For tests for Features A01 or A05, compliance is based on the measured concentration at each location compared against each VOC’s requirement in WELL + tolerance of 5%.
-
For tests of WELL v1 Feature 01, compliance is based on each location either meeting the conditions above or the measured TVOC concentration compared against the requirement in WELL.
Refer to the Performance Verification Guidebook for information on sensor/testing requirements, required testing duration and compliance calculations.
WELL Core:
A05.3 Meet Enhanced Thresholds for Inorganic Gases — 1 point
Applies to: All Spaces.
The following thresholds are met:
Carbon monoxide: 7 mg/m³ [6 ppm] or lower.11
Nitrogen dioxide: 40 µg/m³ [21 ppb] or lower.11
Verification: Performance Test OR Sensor Data
Performance verification: Carbon Monoxide
Test method:
- Minimum of one continuous hour (10 minutes of acclimation time followed by 50 minutes of measurement time), with measurements recorded at least once every minute.
Device requirements:
- Real-time direct reading instrument.
- Measurement range: 0-25 ppm
- Instrument resolution: 0.1 ppm
- On-screen resolution: 1 ppm
- Lower detectable limit: 0.1 ppm
- Calibration: instrument must be within the calibration period
Reporting and compliance:
- Compliance is based on the median value collected during the measurement time at each sampling compared with the WELL requirements.
Performance verification: Nitrogen Dioxide
Test method:
- Duration: up to one hour
Device requirements:
- Measurement range: 0-500 ppb
- Lower detectable limit: 5 ppb
- Calibration: instrument must be within the calibration period
Reporting and compliance:
- Compliance is based on the median value collected during the measurement time at each sampling point compared against the requirement in WELL + a tolerance of 20%.
Refer to the Performance Verification Guidebook for information on sensor/testing requirements, required testing duration and compliance calculations.
WELL Core:
Frequently asked questions
Does my WELL Core project need to sample in both non-leased and leased spaces for all Feature A01 parts if the project is not pursuing the matching Feature A05 parts?
All projects have the option to only pursue select parts under Feature A05, despite being required to pursue all parts under Feature A01. When determining sample quantities, WELL Core projects may pursue testing in only non-leased spaces for the Feature A01 parts for which they are not pursuing the matching Feature A05 part. Refer to the WELL Performance Verification guidebook for more on sample quantities for WELL Core projects pursuing both Feature A01 and Feature A05, Part 1, 2, or 3.
References
- Porta D, Narduzzi S, Badaloni C, et al. Air pollution and cognitive development at age 7 in a prospective Italian birth cohort. Epidemiology. 2016;27(2):228-236. doi:10.1097/EDE.0000000000000405
- U.S. Environmental Protection Agency. Highlights from the Clean Air Act 40th Anniversary. https://www.epa.gov/clean-air-act-overview/highlights-clean-air-act-40th-anniversary.
- Horr, A., Kaushik, A., Mazroei, A., Katafygiotou, A. & Elsarrag E. Occupant productivity and office indoor environment quality : a review of the literature Occupant Productivity and Office Indoor Environment Quality : A Review of the Literature. 2016. http://usir.salford.ac.uk/39106/3/BAE-D-16-00533_final%2520manuscript%5B1%5D.pdf.
- Dorgan, CE, Dorgan C. Assessment of link between productivity and indoor air quality. In: Creating the Productive Workplace. ; 2005. https://www.taylorfrancis.com/books/e/9781134265978/chapters/10.4324%2F9780203696880-20.
- Calderón-Garcidueñas L, Torres-Jardón R, Kulesza RJ, Park S Bin, D’Angiulli A. Air pollution and detrimental effects on children’s brain. The need for a multidisciplinary approach to the issue complexity and challenges. Front Hum Neurosci. 2014;8(AUG):1-7. doi:10.3389/fnhum.2014.00613
- Laumbach RJ, Kipen HM. Respiratory health effects of air pollution: Update on biomass smoke and traffic pollution. J Allergy Clin Immunol. 2012;129(1):3-11. doi:10.1016/j.jaci.2011.11.021
- The Organisation for Economic Co-operation and Development. OECD Environmental Outlook to 2050: The Consequences of Inaction. Paris, France: OECD Publishing; 2012. https://www.naturvardsverket.se/upload/miljoarbete-i-samhallet/internationellt-miljoarbete/multilateralt/oecd/outolook-2050-oecd.pdf.
- U.S. Environmental Protection Agency. NAAQS Table. https://www.epa.gov/criteria-air-pollutants/naaqs-table.
- World Health Organization. Air Quality Guidelines for Particulate Matter, Ozone, Nitrogen Dioxide and Sulfur Dioxide. Geneva, Switzerland; 2005. http://apps.who.int/iris/bitstream/handle/10665/69477/WHO_SDE_PHE_OEH_06.02_eng.pdf;jsessionid=CD44465FAC0A1628540C4A2BDF0B51CD?sequence=1.
- California Office of Environmental Health Hazard Assessment. Acute, 8-hour and Chronic Reference Exposure Level (REL) Summary. https://oehha.ca.gov/air/general-info/oehha-acute-8-hour-and-chronic-reference-exposure-level-rel-summary. Published 2019.
- World Health Organization. WHO Guidelines for Indoor Air Quality – Selected Pollutants. Geneva, Switzerland; 2010. http://www.euro.who.int/__data/assets/pdf_file/0009/128169/e94535.pdf.