WELL v2, Q2 2025 — this page reflects the WELL v2, Q2 2025 addenda of the WELL Building Standard.

Official source: https://v2.wellcertified.com/en/wellv2/thermal%20comfort/feature/9

T09 β Outdoor Thermal Comfort (WELL v2, Q2 2025)

Concept: Thermal Comfort · Type: Optimization · Maximum points: 3

Intent

Address the thermal comfort needs of project occupants in the exterior spaces of the project.

Summary

This WELL feature requires projects to design outdoor spaces to avoid excessive wind and manage elevated temperatures through shading or other strategies.

Issue

As communities expand, development takes the place of natural features of the landscape. By replacing open spaces and vegetation with structures built of materials that retain heat, a phenomenon known as the urban heat island has developed in the urban landscape.1,2 The most prominent feature of an urban heat island is a sustained elevated temperature when compared to the immediately surrounding suburban or undeveloped areas.3 This can lead to adverse health outcomes such as heat-related illness, fatigue, increased breathing and increased heart rate.1,4 In addition, high-rise buildings also can concentrate prevailing winds to higher speeds that result in pedestrian discomfort and dangerous conditions.5

Evidence

Various strategies can be used to mitigate urban heat island effects and improve outdoor thermal comfort, including adding vegetation, providing shading structures, increasing reflectance of building materials and introducing water features.6 The use of trees or vegetation facilitates evapotranspiration and provides shade, contributing to lower surface and air temperatures.1 Co-benefits of introducing urban vegetation and green spaces include improved air quality, water quality (often via improved stormwater management) and savings in energy.7 Shelter canopies address solar radiation and provide relief to thermal stress in extreme temperatures. A shaded surface can be up to 25 °C [45 °F] cooler than the peak temperature of a nearby unshaded surface.7 Reducing surface temperatures of sidewalks, roadways and parking lots can be effectively achieved through a mixture of shading and high-albedo paving materials.8–10 Finally, water bodies can have a positive effect on microclimates in urban areas by moderating extreme temperatures. Small water bodies such as fountains, pools and ponds can regulate temperature fluctuations and help improve thermal comfort during days of extreme heat.11,12 Studies suggest that temperatures around and downwind of water bodies can be 1–2°C [2–4°F] lower compared to surrounding areas.12 Computational fluid dynamics programs and other modeling tools can be used to predict the thermal conditions and likelihood of excessive wind and the effectiveness of countermeasures.5,13

Requirements

T09.1 Manage Outdoor Heat — 1 point

Applies to: All Spaces.

Meet any one of the following options:

Option 1: Outdoor shading

The following areas (if present) are shaded for more than half of daylight hours each day by tree canopies, awnings, or other structures:

Verification: Technical Document (Audited), Beta Feature Feedback Form

Technical Document: Map

Option 2: Temperature modeling

For pedestrian pathways and building entrances, parking spaces, and plazas, seating areas, exercise facilities with a contiguous area of less than {{well-unit}}2500 ft2|230 m2{{/well-unit}} and other outdoor areas of congregation, project provides the following:

Verification: Technical Document (Audited), Beta Feature Feedback Form

Technical Document: Modeling report

Interior projects may achieve this part if the grounds of the base building meet the requirements, even if they are outside of the interior project boundary.


This feature is a beta strategy and has an additional documentation requirement (beta feature feedback form). The feedback form supports IWBI in developing new features that are effective and applicable to projects around the world.

WELL Core:

Meet the requirements in the whole building.

T09.2 Avoid Excessive Wind — 1 point

Applies to: All Spaces.

A computational fluid dynamic model of the building and any adjacent buildings that takes into account at least one day per season (i.e., per quarter) demonstrates the following:

Verification: Technical Document (Audited), Beta Feature Feedback Form

Technical Document: Modeling report

Interior projects may achieve this part if the grounds of the base building meet the requirements, even if they are outside of the interior project boundary.


This feature is a beta strategy and has an additional documentation requirement (beta feature feedback form). The feedback form supports IWBI in developing new features that are effective and applicable to projects around the world.

WELL Core:

Meet the requirements in the whole building.

T09.3 Support Outdoor Nature Access — 1 point

Applies to: All Spaces.

Project achieves the following features: This feature is a beta strategy and has an additional documentation requirement (beta feature feedback form). The feedback form supports IWBI in developing new features that are effective and applicable to projects around the world.

Verification: Beta Feature Feedback Form

WELL Core:

Meet the requirements in the whole building.

Frequently asked questions

When determining shading requirements for specified outdoor areas, how should the percentages be calculated?

The percentages listed in the requirements refer to the total area that is shaded for each type of outdoor space listed, compared with the total area that is present of that space type (e.g., at least 50% of the total area of all pedestrian pathways and building entrances must be shaded).

References

  1. Environmental Protection Agency. Heat Island Cooling Strategies | Heat Island Effect | US EPA.
  2. UCAR Center for Science Education. Urban Heat Islands | UCAR Center for Science Education.
  3. Environmental Protection Agency. Reducing Urban Heat Islands: Compendium of Strategies - Urban Heat Island Basics. Washington, DC; 2008.
  4. Zhang L, Wei D, Hou Y, et al. Outdoor Thermal Comfort of Urban Park—A Case Study. Sustainability. 2020;12(5):1961. doi:10.3390/su12051961
  5. Blocken B, Carmeliet J. Pedestrian wind conditions at outdoor platforms in a high-rise apartment building: generic sub-configuration validation, wind comfort assessment and uncertainty issues. Wind Struct. 2008;11(1):51-70.
  6. Nouri AS, Costa JP, Santamouris M, Matzarakis A. Approaches to outdoor thermal comfort thresholds through public space design: A review. Atmosphere (Basel). 2018;9(3). doi:10.3390/atmos9030108
  7. Environmental Protection Agency. Using Trees and Vegetation to Reduce Heat Islands | Heat Island Effect | US EPA.
  8. Karlessi T, Santamouris M, Apostolakis K, Synnefa A, Livada I. Development and testing of thermochromic coatings for buildings and urban structures. Sol Energy. 2009;83(4):538-551. doi:10.1016/j.solener.2008.10.005
  9. Levinson R, Akbari H, Berdahl P, Wood K, Skilton W, Petersheim J. A novel technique for the production of cool colored concrete tile and asphalt shingle roofing products. Sol Energy Mater Sol Cells. 2010;94(6):946-954. doi:10.1016/j.solmat.2009.12.012
  10. Marceau ML, Vangeem MG. Solar Reflectance of Concretes for LEED Sustainable Sites Credit: Heat Island Effect.; 2007.
  11. Spronken‐Smith RA, Oke TR, Lowry WP. Advection and the surface energy balance across an irrigated urban park. Int J Climatol. 2000;20(9):1033-1047. doi:10.1002/1097-0088(200007)20:9<1033::AID-JOC508>3.0.CO;2-U
  12. Coutts AM, Tapper NJ, Beringer J, Loughnan M, Demuzere M. Watering our cities. Prog Phys Geogr Earth Environ. 2013;37(1):2-28. doi:10.1177/0309133312461032
  13. Park S, Tuller SE, Jo M. Application of Universal Thermal Climate Index (UTCI) for microclimatic analysis in urban thermal environments. Landsc Urban Plan. 2014;125:146-155. doi:10.1016/j.landurbplan.2014.02.014
  14. Netherlands Standards. NEN 8100 : 2006 - Wind Comfort and Wind Danger in the Built Environment.; 2006.