T08 β Enhanced Operable Windows (WELL v2, Q2 2025)

Concept: Thermal Comfort · Type: Optimization · Maximum points: 1

Intent

Provide the benefits of increased outdoor air supply while minimizing any resulting thermal discomfort.

Summary

This WELL feature requires windows that can be opened at different elevations to provide desired air flow at different outdoor temperatures.

Issue

Although use of personally controlled operable windows can improve satisfaction with the indoor air quality and thermal comfort, it may also have negative aspects if outdoor air is polluted or if outdoor weather is very hot or cold.1–3 In cold weather, large openings in windows near occupants can lead to unpleasant draft.

Evidence

Windows which can be opened in multiple modes may provide thermal comfort over a variety of weather conditions. Large openings near the level of the occupants can provide high levels of air exchange and potentially increased air speed and corresponding cooling effect. Small openings near the ceiling allow some air exchange to take place while minimizing the potential for draft, allowing the outdoor air to warm before it reaches the occupants.4

Requirements

T08.1 Provide Windows with Multiple Opening Modes — 1 point

Applies to: All Spaces.

Meet all of the following options:

Option 1: Window design

Operable windows may be opened according to the following requirements (windows which may be opened in both modes may count for both requirements a and b):

This feature is a beta strategy and has an additional documentation requirement (beta feature feedback form). The feedback form supports IWBI in developing new features that are effective and applicable to projects around the world.

Verification: Letter of Assurance – Designer, On-site Photographs, Beta Feature Feedback Form

Photographs should showcase: 
1) The open window.
2) The mechanism occupants can use to open the window.
3) A measurement tape confirming height of open window from finished floor.

Quantity:
1) At least 10% of windows, up to a maximum of five windows. Photographs should be distributed throughout the project and across the types of operable windows, as applicable.

Option 2: Window operation

Instructions for window operation are provided through signage or other communications to regular occupants to indicate the following:

Verification: Professional Narrative

Projects may only achieve this part if Feature A07 Part 1 is also achieved.

WELL Core:

Meet the requirements in the whole building.

References

  1. Burge S, Hedge A, Wilson S, Bass JH, Robertson A. Sick building syndrome: A study of 4373 office workers. Ann Occup Hyg. 1987;31(4 A):493-504. doi:10.1093/annhyg/31.4A.493
  2. Horr, A., Kaushik, A., Mazroei, A., Katafygiotou, A. & Elsarrag E. Occupant productivity and office indoor environment quality : a review of the literature Occupant Productivity and Office Indoor Environment Quality : A Review of the Literature. 2016. http://usir.salford.ac.uk/39106/3/BAE-D-16-00533_final%2520manuscript%5B1%5D.pdf.
  3. Brager GS. Benefits of Improving Occupant Comfort and Well-being in Buildings. In: Proceedings of the 4th International Holcim Forum for Sustainable Construction: The Economy of Sustainable Construction. Mumbai; 2013:181–194. https://src.lafargeholcim-foundation.org/dnl/93603859-d59e-498a-b056-405d16e39171/F13_OrangeWS_Brager.pdf.
  4. Van den Engel PJW, Kurvers SR. The scope of inducing natural air supply via the façade. Archit Sci Rev. 2017;60(3):215-224. doi:10.1080/00038628.2017.1300765
  5.  Rijksdienst voor Ondernemend Nederland. Programma van Eisen Frisse Scholen 2015 – Versie September 2015 (Program of Requirements Fresh Schools). Nederland; 2015.