S06 Minimum Background Sound (WELL v2, Q2 2025)
Concept: Sound · Type: Optimization · Maximum points: 2
Intent
Increase acoustical privacy within and between occupied spaces.Summary
This WELL feature requires the use of dedicated artificial sound to uniformly increase speech privacy between occupied spaces.Issue
Speech privacy can be described as the signal-to-noise ratio, or sound blocking and sound cover, of perceptible speech reaching a listener.1 Ambient background sound, which can include artificial sound sources, can increase speech privacy to comfortable levels.2,3 However, ambient background noise provided by HVAC systems alone is shown to fluctuate by zone and by as much as 15 dBA or more in a given year.4 Some HVAC systems, like chilled beams, offer little to no ambient sound contribution and result in quiet interiors, where speech is readily intelligible and distracting. In offices and patient rooms where speech privacy is critical between regularly occupied spaces, a combination of reliable background sound is needed where partitions do not perform above a minimum STC-30.5Evidence
Consistent background sound can be delivered to a space using an adjustable array of loudspeakers located such that sound is uniformly distributed.6,7 These systems are programmed to output a sound source similar to the sound of air flowing through HVAC. The sound source is broad-band and designed to elevate ambient background sound level to improve the signal-to-noise ratio and reduce speech perception between enclosed and open environments.8,9Requirements
S06.1 Provide Minimum Background Sound — 1 point
Applies to: Office Spaces.
The following requirements are met:
The sound masking system is verified by a professional sound masking system installer in accordance with ASTM 1573-18 or equivalent standard.
A sound masking system is installed in open areas and enclosed rooms designated as quiet zones, circulation zones and in areas where workstations are present.
The sound masking system produces a 1/3 octave band adjustable output signal and minimum frequency spectrum of 100 Hz to 5 kHz.
The sound masking system is commissioned such that the following sound pressure levels are not exceeded:
- Open areas designated as quiet zones, circulation zones and areas where workstations are present: 48 dBA.
- Enclosed rooms labeled as quiet zones: 42 dBA.
Verification: Technical Document (Audited)
Other - Commissioning report
WELL Core:
To earn this optimization, the requirements should be met in the whole building.
S06.2 Provide Enhanced Speech Reduction — 1 point
Applies to: All Spaces.
The project achieves the following features and parts:
Achieve two points in either Feature S03 Part 2 - Achieve Sound Isolation at Walls or Feature S05 Part 1 – Implement Sound Reducing Surfaces.
Feature S06 Part 1 – Provide Minimum Background Sound.
N/A
WELL Core:
Meet these requirements in non-leased spaces. To earn and additional point, also meet these requirements in leased spaces.Frequently asked questions
If the sound level of my project's HVAC system is below these level limits as applicable, can this existing system be used in place of a dedicated sound masking system?
No - dedicated sound masking systems are intended to provide consistent and uniform background sound, unlike an HVAC system which cycles and varies in sound output and uniformity over time.References
- Venetjoki N, Kaarlela-Tuomaala A, Keskinen E, Hongisto V. The effect of speech and speech intelligibility on task performance. Ergonomics. 2006;49(11):1068-1091. doi:10.1080/00140130600679142
- Hongisto V. Effects of sound masking on workers - a case study in a landscaped office. 9th Int Congr Noise as a Public Heal Probl. 2008;(1979):1-8.
- Larm P, Keränen J, Helenius R, Hakala J, Hongisto V. Acoustics in open-plan offices -- A laboratory study. Forum Acusticum. 2005;(Figure 1):2021-2025.
- Hongisto V. Effect of sound masking on workers in an open office. Acoust 08 Paris. 2008;June 29-Ju(1979):537-542. doi:10.1121/1.2932454
- Hongisto V, Oliva D, Keränen J. Subjective and objective rating of airborne sound insulation - living sounds. Acta Acust united with Acust. 2014;100(5):848-863. doi:10.3813/AAA.918765
- Bradley JS. The acoustical design of conventional open plan offices. Can Acoust. 2003;27(3):23-31. doi:NRCC-46274 A
- Veitch JA, Bradley JS, Legault LM, Norcross SG, Svec JM. IRC-IR-846: Masking speech in open-plan offices with simulated ventilation noise: Noise level and spectral composition effects on acoustic satisfaction. 2002;(November):1-56.
- DeLoach AG, Carter JP, Braasch J. Tuning the cognitive environment: Sound masking with “natural” sounds in open-plan offices. J Acoust Soc Am. 2015;137(4):2291-2291. doi:10.1121/1.4920363
- Alvarsson JJ, Wiens S, Nilsson ME. Stress recovery during exposure to nature sound and environmental noise. Int J Environ Res Public Health. 2010;7(3):1036-1046. doi:10.3390/ijerph7031036