S05 Sound Reducing Surfaces (WELL v2, Q2 2025)
Concept: Sound · Type: Optimization · Maximum points: 2
Intent
Design spaces with sound reducing surfaces to minimize the buildup of speech or other unwanted sound.Summary
This WELL feature requires the use of acoustic materials that absorb and/or block sound to support concentration and reduce reverberation.Issue
Increases in reverberation are commonly caused by lack of acoustical absorption.1 When spaces are designed with hard reflective ceilings and walls, perception of noise increases with an increase in ambient, reflected noise that decays in level at a longer rate.2,3 When open collaborative spaces lack acoustical absorption at ceilings or partial height barriers, workers can become distracted by reflected sound, especially if that speech is perceptible.3–6 Conversely, in learning environments, reverberation can impair a listener’s comprehension of speech due to poor speech intelligibility, especially when listeners are hard of hearing, expending a greater auditory workload to process speech resulting in reduced task performance.7–12 In rooms where teleconferencing or audio equipment introduces amplified sound, spaces without adequate acoustical treatment are subject to higher functioning background noise levels, which may be heard in neighboring spaces.1,13–15 Lack of reflected sound control in spaces for conferencing can impact the quality of speech intelligibility over teleconferencing equipment.Evidence
Providing
acoustical treatment that significantly reduces sound across human speech
frequencies can greatly reduce unwanted buildup of reflected sound.1 Ceilings typically provide the greatest area
of coverage where highly absorptive materials can offer the best performance in
reducing reverberation and controlling speech intelligibility and occupied
noise levels.3,16,17 Wall treatment can reduce reflections that
impact performance of speech intelligibility with teleconferencing equipment.1
Requirements
S05.1 Implement Sound Reducing Surfaces — 1–2 points (max 2)
Applies to: All Spaces; excluding Dwelling Units.
For projects in which the room types listed in the table cumulatively make up at least 10% of occupiable project area, the following requirements are met:
Acoustical furnishings meet the criteria shown in the following table:
Room Type
Metric
Tier 1
{{well-points}}1 Point|0.5 Points{{/well-points}}
Tier 2
{{well-points}}2 Points|1 Point{{/well-points}}
Open workspaces
Minimum NRC OR Alpha-w
0.75 for at least 75% of available ceiling area
0.90 for all available ceiling area1,18
Minimum furniture height and NRC OR Alpha-w
N/A Partial height barriers with a minimum height of {{well-unit}}4 ft|1.2 m{{/well-unit}} above finished floor and a minimum NRC OR Alpha-w value of 0.70 between all opposing workstations1
Areas for conferencing and learning
Minimum NRC OR Alpha-w at ceilings
0.75 for at least 50% of available ceiling area
0.90 for all available ceiling area
Minimum NRC OR Alpha-w at walls
0.75 on at least 25% of one wall
0.80 on at least 25% of two perpendicular walls
Areas for dining
Minimum NRC OR Alpha-w at ceilings
0.75 on at least 50% of available ceiling area
0.90 for all available ceiling area
Verification: Technical Document (Audited)
Design specification
WELL Core:
Meet these requirements in non-leased spaces. To earn an additional point, also meet these requirements in leased spaces.
WELL Core projects where non-leased space represents 40% or more of total project area may pursue the additional point without achieving the feature requirements in tenant spaces. Projects utilizing this pathway should include a note on the documentation required by the feature.
References
- General Services Administration. Sound Matters: How to Achieve Acoustic Comfort in the Contemporary Office. 2011. https://www.wbdg.org/FFC/GSA/gsa_soundmatters.pdf.
- Bradley. Speech Intelligibility Studies in Classrooms. J Acoust Soc Am. 1986.
- Bradley JS. The acoustical design of conventional open plan offices. Can Acoust. 2003;27(3):23-31. doi:NRCC-46274 A
- Venetjoki N, Kaarlela-Tuomaala A, Keskinen E, Hongisto V. The effect of speech and speech intelligibility on task performance. Ergonomics. 2006;49(11):1068-1091. doi:10.1080/00140130600679142
- Jensen KL, Arens E, Zagreus L. Acoustical Quality in Office Workstations , As Assessed By Occupant Surveys. Indoor Air 10th Int Conf indoor air Qual Clim. 2005:2401-2405. doi:10.1111/j.1600-0668.2011.00745.x
- Kim J, de Dear R. Workspace satisfaction: The privacy-communication trade-off inopen-plan offices. J Environ Psychol. 2013;36:18-26. doi:10.1016/j.jenvp.2013.06.007
- Klatte M, Hellbrück J, Seidel J, Leistner P. Effects of Classroom Acoustics on Performance and Well-Being in Elementary School Children: A Field Study. Environ Behav. 2010;42(5):659-692. doi:10.1177/0013916509336813
- Bennetts L, Flynn M. Improving the classroom listening skills of children with Down syndrome by using sound-field amplification. Downs Syndr Res Pract. 2002;8(1):19-24.
- Bradley JS. Speech intelligibility studies in classrooms. J Acoust Soc Am. 1986;80(3).
- Cheesman MF, Jennings MB, Klinger L. Assessing communication accessibility in the university classroom: Towards a goal of universal hearing accessibility. Work. 2013;46(2):139-150.
- Bradley JS. Speech intelligibility studies in classrooms Speech intelligibility. 2009;846(1986). doi:10.1121/1.393908
- Peters LJ. Auditory Performance: A Model to Predict Task Performance as a Function of Auditory Workload: Overview. In: Proceedings of the Human Factors and Ergonomics Society Annual Meeting. ; 1991.
- InfoComm International. AV / IT Infrastructure Guidelines for Higher Education.
- Larsen JB, Vega A, Ribera JE. The Effect of Room Acoustics and Sound-Field Amplification on Word Recognition Performance in Young Adult Listeners in Suboptimal Listening Conditions. Am J Audiol. 2008;17(1):50-59.
- Watson A, Sasse MA. Measuring Perceived Quality of Speech and Video in Multimedia Conferencing Applications. :1-6.
- Pierrette M, Parizet E, Chevret P, Chatillon J. Noise effect on comfort in open-space offices: development of an assessment questionnaire. Ergonomics. 2015;58(1):96-106. doi:10.1080/00140139.2014.961972
- Larm P, Keränen J, Helenius R, Hakala J, Hongisto V. Acoustics in open-plan offices -- A laboratory study. Forum Acusticum. 2005;(Figure 1):2021-2025.