WELL v2, Q2 2025 — this page reflects the WELL v2, Q2 2025 addenda of the WELL Building Standard.

Official source: https://v2.wellcertified.com/en/wellv2/sound/feature/4

S04 Reverberation Time (WELL v2, Q2 2025)

Concept: Sound · Type: Optimization · Maximum points: 2

Intent

Design spaces in accordance with comfortable reverberation times that support speech intelligibility, vocal effort and are conducive to concentration. 

Summary

This WELL feature requires that steps be taken to address acoustical comfort, by controlling reverberation time based on room functionality.

Issue

Reverberation time is the length of time taken for a sound to decay by 60 dB from an initial impulse level. The length of reverberation time is a function of room size, surface area and sound absorbing properties of surface finishes. Spaces with longer reverberation times may be larger in volume with hard surfaces that reflect sound. Spaces with shorter reverberation may be smaller with softer surfaces that absorb sound. Spaces with high reverberation may have increased ambient noise levels and reduce speech intelligibility (e.g., public address, speech reinforcement and unamplified speech). Studies have shown that high reverberation times in classrooms increase auditory workload in students and reduce cognition, memory retention and concentration.1–4 Similarly, studies have shown that high reverberation reduces speech intelligibility among hard of hearing and non-native speaking populations.5–8

Evidence

Reverberation time can be controlled by adding absorptive surface finishes at ceilings, walls and furniture.9–11 Projects that can alter room geometry can change layouts and room dimensions to support optimal reverberation times, as needed. Reducing reflective surfaces, such as glass, drywall, stone or similar, will also reduce reflected sound energy, which increases reverberation time. Reducing reverberation time also allows audio equipment for telecommunication/AV, speech reinforcement or public address to operate with higher speech intelligibility performance.5,12–14

Requirements

S04.1 Achieve Reverberation Time Thresholds — 2 points

Applies to: All Spaces; excluding Dwelling Units, Guest Rooms.

Meet any one of the following options:

Option 1: Reverberation time, design

For projects in which the room types listed in the table cumulatively make up at least 10% of occupiable project area, the following requirements are met:

Where room types include multiple use types (e.g., learning and fitness) use the limits that include the lower reverberation time or range.

Verification: Technical Document (Audited)

Modeling Report

Option 2: Reverberation time, performance

For projects in which the room types listed in the table cumulatively make up at least 10% of occupiable project area, the following requirements are met:

Where room types include multiple use types (e.g., learning and fitness) use the limits that include the lower reverberation time or range.

Refer to the Performance Verification Guidebook for information on sensor/testing requirements, required testing duration and compliance calculations.

Verification: Performance Test, Technical Document (Individual)

Technical Document: A list of room volumes for all applicable spaces.

Performance verification: Reverberation Time

Test method:

Device requirements:

Balloon of minimum diameter 0.4 m [16 in]

OR

Loudspeaker:

Reporting and compliance:

WELL Core:

Meet these requirements in non-leased spaces. To earn an additional point, also meet these requirements in leased spaces.

WELL Core projects where non-leased space represents 40% or more of total project area may pursue the additional point without achieving the feature requirements in tenant spaces. Projects utilizing this pathway should include a note on the documentation required by the feature.    

Frequently asked questions

Are open plan offices included in any of the room types listed in this feature?

No, open plan offices are not covered by the requirements of this feature. Reverberation time values can fluctuate greatly across the floor plate of open offices, making reverberation time difficult to quantify and design. Furthermore, there is not yet strong evidence that links higher reverberation times in open offices to adverse conditions for occupants. More suitable metrics include articulation index (AI), spatial decay of sound (D2s), radius of distraction (rD), and background sound (dBA).

References

  1. Klatte M, Bergström K, Lachmann T. Does noise affect learning? A short review on noise effects on cognitive performance in children. Front Psychol. 2013;4(August):1-6. doi:10.3389/fpsyg.2013.00578
  2. Klatte M, Hellbrück J, Seidel J, Leistner P. Effects of Classroom Acoustics on Performance and Well-Being in Elementary School Children: A Field Study. Environ Behav. 2010;42(5):659-692. doi:10.1177/0013916509336813
  3. Venetjoki N, Kaarlela-Tuomaala A, Keskinen E, Hongisto V. The effect of speech and speech intelligibility on task performance. Ergonomics. 2006;49(11):1068-1091. doi:10.1080/00140130600679142
  4. Belojević G, Öhrström E, Rylander R. Effects of noise on mental performance with regard to subjective noise sensitivity. Int Arch Occup Environ Health. 1992;64(4):293-301. doi:10.1007/BF00378288
  5. Ihrig W, The National Academies of Sciences Engineering Medicine, Transportation Research Board. Improving Intelligibility of Airport Terminal Public Address Systems. 2017. doi:10.17226/24839
  6. Heylighen A, Rychtarikova M, Vermeir G. Designing Spaces for Every Listener. Univers Access Inf Soc. 2010;9(3):283-292.
  7. The National Disability Authority’s Centre for Excellence in Universal Design. Building for Everyone: A universal design approach. 2012:4-106.
  8. Centre for Excellence in Universal Design. Internal environment and services. In: Building for Everyone: A Universal Design Approach. Centre for Excellence in Universal Design. http://universaldesign.ie/Built-Environment/Building-for-Everyone/.
  9. Architectural Joint Technical Committee AV-004 Acoustical. AS/NZS 2107:2016. 2016:24.
  10. General Services Administration. Sound Matters: How to Achieve Acoustic Comfort in the Contemporary Office. 2011. https://www.wbdg.org/FFC/GSA/gsa_soundmatters.pdf.
  11. General Services Administration, Service PB. PBS-P100 Facilities Standards for the Public Buildings Service. 2016;(March):333. doi:10.1017/CBO9781107415324.004
  12. ANSI/INFOCOMM. ANSI/INFOCOMM 10:2013 Audiovisual Systems Performance Verification. 2013.
  13. InfoComm International. AV / IT Infrastructure Guidelines for Higher Education.
  14. Publication BSIS. BSI Standards Publication - Sound system equipment - Part 4. 2011.