WELL v2, Q2 2025 — this page reflects the WELL v2, Q2 2025 addenda of the WELL Building Standard.

Official source: https://v2.wellcertified.com/en/wellv2/light/feature/7

L07 Visual Balance (WELL v2, Q2 2025)

Concept: Light · Type: Optimization · Maximum points: 1

Intent

Create lighting environments that enhance visual comfort.

Summary

This WELL feature requires projects to develop and implement strategies to create a visually comfortable lighting environment.

Issue

A lighting environment may utilize different kinds of light sources, including daylighting and different types of electric lighting technology. Lighting is planned across spaces to achieve the required ambience and energy efficiency goals. However, fluctuating light levels impact the visual comfort of occupants and could lead to eye fatigue.1 Sudden increases and decreases in brightness can cause a high level of visual discomfort.2 Constant changes in lighting have been linked to distraction from the task at hand, which can decrease productivity and impact well-being.3

Evidence

Development of a lighting layout and operations schedule to complement the lighting design in a space is key to increasing the comfort of users. Evidence suggests that thoughtful planning of lighting in a space that takes into account color temperature, daylight and electric light supports a visually comfortable lighting environment.4,5 Consideration of the ages of users, tasks performed and existing physical features in the space are also integral to creating a productive space.

Requirements

L07.1 Balance Visual Lighting — 1 point

Applies to: All Spaces.

Meet any one of the following options:

Option 1: Parameters for visual balance

Ambient lighting in all regularly occupied spaces meets at least three of the following requirements:

Verification: Professional Narrative

Option 2: Design for visual balance

Lighting is designed by a lighting professional and takes into account the following considerations:

Verification: Professional Narrative

WELL Core:

Meet these requirements in non-leased spaces. To earn an additional point, also meet these requirements in leased spaces.

WELL Core projects where non-leased space represents 40% or more of total project area may pursue the additional point without achieving the feature requirements in tenant spaces. Projects utilizing this pathway should include a note on the documentation required by the feature.    

Frequently asked questions

Are vision glazing / windows considered 'surfaces’?

Windows and other glazed surfaces are not considered 'surfaces' for the purposes of this feature.

References

  1. Kim SY, Kim JJ. The effect of fluctuating illuminance on visual sensation in a small office. Indoor Built Environ. 2007;16(4):331-343. doi:10.1177/1420326X06079947
  2. Illuminating Engineering Society. Lighting Handbook. 10th ed. Illuminating Engineering Society; 2011. https://www.ies.org/store/lighting-handbooks/lighting-handbook-10th-edition/.
  3. Veitch JA, Newsham GR, Boyce PR, Jones CC. Lighting appraisal, well-being and performance in open-plan offices: A linked mechanisms approach. Light Res Technol. 2008;40(2):133-148. doi:10.1177/1477153507086279
  4. Linhart F, Scartezzini JL. Evening office lighting - visual comfort vs. energy efficiency vs. performance? Build Environ. 2011;46(5):981-989. doi:10.1016/j.buildenv.2010.10.002
  5. Shen E, Hu J, Patel M. Energy and visual comfort analysis of lighting and daylight control strategies. Build Environ. 2014;78:155-170. doi:10.1016/j.buildenv.2014.04.028