WELL v2, Q2 2025 — this page reflects the WELL v2, Q2 2025 addenda of the WELL Building Standard.

Official source: https://v2.wellcertified.com/en/wellv2/light/feature/6

L06 Daylight Simulation (WELL v2, Q2 2025)

Concept: Light · Type: Optimization · Maximum points: 2

Intent

Ensure indoor daylight exposure through daylight simulation strategies.

Summary

This WELL feature requires projects to conduct daylight simulation calculations to make informed decisions around fenestration and shading, so as to provide appropriate daylight exposure for occupants. 

Issue

The way buildings are designed has an enormous impact on occupant exposure to daylight.1 Exposure to daylight has been proven to have a substantial impact on mood, circadian health and productivity.1,2 Studies have associated lack of exposure to daylight with a disruption in the circadian rhythms of humans and a decrease in sleep quality. Students have been shown to perform better when they have access to windows that can be opened.3 Indoor spaces with daylight exposure have been shown to have fewer bacteria, compared to spaces without any light exposure.4  

Evidence

Building design and planning has a substantial impact on the amount of daylight in an indoor space. With the myriad of solutions available for daylight ingress and shading, indoor daylight exposure can be optimized by conducting simulations. Daylight simulations can inform choices for shading, support fenestration design, as well as the interior layout of a spaces.5–7

Requirements

L06.1 Conduct Daylight Simulation — 1–2 points (max 2)

Applies to: All Spaces; excluding Dwelling Units, Guest Rooms.

The project demonstrates, through computer simulations, that the following conditions are achieved:

Verification: Technical Document (Audited)

Modeling report

Applies to: Dwelling Units, Guest Rooms.

The project demonstrates, through computer simulations, that the following conditions are achieved:

Verification: Technical Document (Audited)

Modeling report

WELL Core:

Meet these requirements in the whole building. If finishes have not finalized may use the following default surface reflectances:

If the layout of leased spaces is not yet known, the entire leased space is to be considered regularly occupied.

Frequently asked questions

When calculating sDA and ASE in daylight modeling, can you clarify if the interior and exterior shades/blinds can be modeled for analysis?

The exterior shades/blinds should be modeled for analysis in accordance with IES LM-83 which defines the calculation of Spatial Daylight Autonomy (sDA) and Annual Sunlight Exposure (ASE). 

Interior glare control (shades/blinds) should not be used for the ASE analysis, per the methodology outlined in IES LM-83, Section 3.2.6, but are allowed for the sDA analysis.

References

  1. Boubekri M, Cheung IN, Reid KJ, Wang CH, Zee PC. Impact of windows and daylight exposure on overall health and sleep quality of office workers: A case-control pilot study. J Clin Sleep Med. 2014;10(6):603-611. doi:10.5664/jcsm.3780
  2. Amundadottir ML, Rockcastle S, Khanie MS, Andersen M. A human-centric approach to assess daylight in buildings for non - visual health potential, visual interest and gaze behavior. Build Environ. 2016;113:1-40.
  3. Heschong L. Daylighting in Schools: An Investigation into the Relationship between Daylighting and Human Performance. Detailed Report. Hmg-R-9803. 1999:140. http://eric.ed.gov/?id=ED444337.
  4. Fahimipour AK, Hartmann EM, Siemens A, et al. Daylight exposure modulates bacterial communities associated with household dust 06 Biological Sciences 0605 Microbiology. Microbiome. 2018;6(1). doi:10.1186/s40168-018-0559-4
  5. Sherif A, Sabry H, Wagdy A, Mashaly I, Arafa R. Shaping the slats of hospital patient room window blinds for daylighting and external view under desert clear skies. Sol Energy. 2016;133:1-13. doi:10.1016/j.solener.2016.03.053
  6. Wagdy A, Sherif A, Sabry H, Arafa R, Mashaly I. Daylighting simulation for the configuration of external sun-breakers on south oriented windows of hospital patient rooms under a clear desert sky. Sol Energy. 2017;149:164-175. doi:10.1016/j.solener.2017.04.009
  7. Shen E, Hu J, Patel M. Energy and visual comfort analysis of lighting and daylight control strategies. Build Environ. 2014;78:155-170. doi:10.1016/j.buildenv.2014.04.028