L05 Daylight Design Strategies (WELL v2, Q2 2025)

Concept: Light · Type: Optimization · Maximum points: 4

Intent

Provide daylight exposure indoors through design strategies.

Summary

This WELL feature requires projects to design spaces to integrate daylight into indoor environments, so that daylight may be used for visual tasks along with electric lighting. It also provides individuals with a connection to outdoor spaces through windows.

Issue

Humans spend approximately 90% of their time indoors.1 The way buildings are designed has an enormous impact on occupant exposure to daylight.2 Exposure to daylight has been proven to have a substantial impact on mood, circadian health and productivity.2,3 Studies have associated lack of exposure to daylight with a disruption in the circadian rhythms of humans and a decrease in quality of sleep.2 Rooms with large windows also reduce recovery time for patients suffering from severe depression and those recuperating after heart attacks, compared to similarly afflicted patients in rooms with windows facing buildings or other obstructions.4–6 Window characteristics have also been found to have an impact on students' performance in schools.7 Students have been shown to perform better, when they have access to windows that can be opened.8 Studies also show strong links between quality of views in office environments and performance of employees.9 Indoor spaces with daylight exposure have been shown to have fewer bacteria, compared to spaces without any light exposure.10

Evidence

Building design and interior layout have a substantial impact on the amount of daylight in an indoor space. Indoor daylight should be accounted for at all stages of building planning from architectural and façade design to interior design and layout. Indoor daylight planning should be coupled with glare control strategies, such as integrating shading for all windows. 

Requirements

L05.1 Implement Daylight Plan — 1–2 points (max 2)

Applies to: All Spaces; excluding Dwelling Units, Guest Rooms.

The following requirement is met:

Verification: Technical Document (Audited)

Architectural drawings and glazing specifications

Applies to: Dwelling Units, Guest Rooms.

The following requirement is met:

Verification: Technical Document (Audited)

Architectural drawings

WELL Core:

Meet these requirements in the whole building. For the interior layout option, a sample furniture layout should be submitted for documentation and shared with tenants.

L05.2 Integrate Solar Shading — 1–2 points (max 2)

Applies to: All Spaces; excluding Dwelling Units, Guest Rooms.

The following requirements are met in regularly occupied spaces:

Verification: On-site Photographs, Policy and/or Operations Schedule

Photographs should include
1) Shading system engaged on window.
2) Control mechanism/program for shading system.

Quantity: Photographs at least 10% of windows, up to a maximum of five windows.

Applies to: Dwelling Units, Guest Rooms.

The following requirements are met in dwelling units:

Verification: On-site Photographs, Letter of Assurance – Designer

WELL Core:

Meet these requirements in the whole building for each floor or for each tenant, whichever is smaller. Projects can either install shading in tenant spaces or provide a budget to tenants tied to the implementation of feature requirements. If the project owner does not have access to leased space, the owner can include shade opening requirements in the lease language for the tenant to implement.

Frequently asked questions

The building envelope has 2 different types of glazing. The glazing in the line of vision has a VLT greater than 40%, and the rest of the glazing does not. Can the project team consider a weighted average of all glazing to determine if as a whole they have a VLT greater than 40%?

The project team may use a weighted average per facade to meet the requirement of VLT greater than 40%.

What kind of products can be used to meet the shading requirements of Feature L05, Part 2?

Any type of system that substantially reduces the amount of solar glare through the building fenestration may be used, such as shades, curtains, blinds, or electrochromic glass. 

The VLT levels of glazing in my project are unknown. Is there a way to calculate the VLT levels of existing windows?

If the project does not have VLT levels of existing windows, the VLT can be manually calculated with the following method. Take lux measurements with a calibrated instrument inside and outside the glazing at the same point (both placed vertically against the glazing facing outwards). VLT= Indoor measurement / Outdoor measurement. You would need to take measurements at three separate locations during the day with little to no time between the indoor measurement and outdoor. These measurements can then be averaged to determine the VLT of the windows. 

Are there limitations on the height of workstation partitions?

The intent of this feature is to design spaces that integrate daylight into indoor environments. To this end, it is counter-productive to have tall opaque obstructions occupying the space between envelope glazing and workstations. As such, there should be no opaque obstructions higher than 4ft [1.2 m] within the distance specified by the feature language.

References

  1. Klepeis NE, Nelson WC, Ott WR, et al. The National Human Activity Pattern Survey (NHAPS): A resource for assessing exposure to environmental pollutants. J Expo Anal Environ Epidemiol. 2001;11(3):231-252. doi:10.1038/sj.jea.7500165
  2. Boubekri M, Cheung IN, Reid KJ, Wang CH, Zee PC. Impact of windows and daylight exposure on overall health and sleep quality of office workers: A case-control pilot study. J Clin Sleep Med. 2014;10(6):603-611. doi:10.5664/jcsm.3780
  3. Amundadottir ML, Rockcastle S, Khanie MS, Andersen M. A human-centric approach to assess daylight in buildings for non - visual health potential, visual interest and gaze behavior. Build Environ. 2016;113:1-40.
  4. Beauchemin KM, Hays P. Dying in the dark: Sunshine, gender and outcomes in myocardial infarction. J R Soc Med. 1998;91(7):352-354. doi:10.1177/014107689809100703
  5. Beauchemin KM, Hays P. Sunny hospital rooms expedite recovery from severe and refractory depressions. J Affect Disord. 1996;40(1-2):49-51. doi:10.1016/0165-0327(96)00040-7
  6. Joarder AR, Price ADF. Impact of daylight illumination on reducing patient length of stay in hospital after coronary artery bypass graft surgery. Light Res Technol. 2012;45(4):435-449. doi:10.1177/1477153512455940
  7. Heschong L, Wright RL, Okura S. Daylighting impacts on human performance in school. J Illum Eng Soc. 2002;31(2):101-114. doi:10.1080/00994480.2002.10748396
  8. Heschong L. Daylighting in Schools: An Investigation into the Relationship between Daylighting and Human Performance. Detailed Report. Hmg-R-9803. 1999:140. http://eric.ed.gov/?id=ED444337.
  9. California Energy Commission. Windows and Offices: A Study of Work Performance and the Indoor Environment. 2003. doi:10.1175/1520-0450(1998)037<0414:TDFBIM>2.0.CO;2
  10. Fahimipour AK, Hartmann EM, Siemens A, et al. Daylight exposure modulates bacterial communities associated with household dust 06 Biological Sciences 0605 Microbiology. Microbiome. 2018;6(1). doi:10.1186/s40168-018-0559-4