WELL v2, Q2 2025 — this page reflects the WELL v2, Q2 2025 addenda of the WELL Building Standard.

Official source: https://v2.wellcertified.com/en/wellv2/thermal%20comfort/feature/2

T02 Verified Thermal Comfort (WELL v2, Q2 2025)

Concept: Thermal Comfort · Type: Optimization · Maximum points: 3

Intent

Enhance thermal comfort and promote human productivity, by ensuring that a substantial majority of building users (above 80%) perceive their environment as thermally acceptable.

Summary

This WELL feature requires projects to provide high levels of thermal comfort, by determining occupant satisfaction through a survey.

Issue

Due to the strong influence of the thermal comfort, standards establish that building’s thermal environment must satisfy a minimum of 80% of occupants to be considered acceptable.1 However, despite having established standards, studies have also shown that only 11% of office buildings surveyed in the U.S. provide thermal environments that meet generally accepted goals of human satisfaction2. Similarly, as many as 41% of office workers have expressed dissatisfaction with the thermal environment.2,3  Building users who are satisfied with their thermal environment have been shown to be more productive in the workplace,2 while thermal discomfort is associated with sick building syndrome symptoms and other conditions that lead to a decrease in productivity.2,4

Evidence

Building occupants are an invaluable source of information that can be used for improving the performance of buildings. Thermal comfort surveys allow projects to objectively gauge which building services and design features are or are not performing well and help to prioritize the steps needed to improve occupant thermal comfort satisfaction and workplace productivity. If survey results indicate that percentage of occupants dissatisfied with thermal conditions in the building exceeds the targeted thresholds, it is necessary to develop a detailed plan for action and commitment to address occupant dissatisfaction with thermal conditions.

Requirements

T02.1 Survey for Thermal Comfort — 2–3 points (max 3)

Applies to: All Spaces.

A post-occupancy survey is administered at least twice a year, including once in June, July or August and once in December, January or February. For buildings located in tropical regions, the survey may be administered twice a year, at least four months apart. Survey is administered at least six months after occupancy, which satisfies the following conditions:

Verification: Technical Document (Individual)

Technical Document: Survey information including:

WELL Core:

Meet these requirements in the whole building. All regular occupants must be invited to participate in the survey. The scope of the survey may be limited to thermal conditions in non-leased spaces.

Frequently asked questions

If a project team would like to submit documentation shortly after construction completion, can it comply with this feature?

No, project teams must wait to conduct the survey until 6 months has passed after the tenants have moved into the space, and have the results readily available. For initial certification, only the results of this first survey are required to demonstrate compliance.

Can the post-occupancy survey be administered if a project has reduced occupancy (e.g.: COVID-19 protocols, reduced student population during summer school)?

Yes, the post-occupancy survey can be administered at reduced occupancy as long as the surveys are administered to the entire population of reduced regular occupants and the minimum number of responses and thermal comfort satisfaction thresholds are met for that reduced population. Subsequent survey responses must be administered to all regular occupants (or the number of regular occupants during the month in which the survey is administered) and the minimum response rate must be met for that population of regular occupants.

References

  1. Kim J, Schiavon S, Brager G. Personal comfort models – A new paradigm in thermal comfort for occupant-centric environmental control. Build Environ. 2018;132:114-124. doi:10.1016/j.buildenv.2018.01.023
  2. Huizenga C, Abbaszadeh S, Zagreus L, Arens EA. Air Quality and Thermal Comfort in Office Buildings: Results of a Large Indoor Environmental Quality Survey. In: Proceedings of Healthy Buildings. Vol III. ; 2006:393-397. http://escholarship.org/uc/item/7897g2f8;jsessionid=CEA1E13173D8003D5F74BD638E71785C.
  3. Frontczak M, Schiavon S, Goins J, Arens E, Zhang H, Wargocki P. Quantitative relationships between occupant satisfaction and satisfaction aspects of indoor environmental quality and building design. Indoor Air. 2012;22(2):119-131. doi:10.1111/j.1600-0668.2011.00745.x
  4. Wargocki P. The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity. Indoor Air. 2000;10(4):222-236. doi:10.1034/j.1600-0668.2000.010004222.x
  5. American Society of Heating Refrigerating and Air-Conditioning Engineers. ASHRAE 55-2013: Thermal Environmental Conditions for Human Occupancy. 2013. https://www.techstreet.com/ashrae/standards/ashrae-55-2013?product_id=1868610.