X06 VOC Restrictions (WELL v2, Q2 2025)

Concept: Materials · Type: Optimization · Maximum points: 4

Intent

Minimize the impact of volatile organic compounds (VOCs) emitted by products on indoor air quality.

Summary

This WELL feature requires adherence to emission thresholds for materials placed inside the building envelope.  

Issue

VOCs encompass a wide group of volatile substances of both natural and artificial origins which have a wide range of health effects from nose, eye and throat irritation, headaches and nausea to liver, kidney and central nervous system damage.1 Furthermore, some select VOCs are known or suspected carcinogens.1 While these compounds are present outside, buildings are a net source due to human activities, cleaning practices and emissions from materials.2 Newly installed furniture, insulation, flooring as well as wet-applied products such as paints, adhesives, sealants and coatings can significantly introduce VOCs into living spaces3 for approximately one to two years,4 and sometimes causing elevated concentrations in enclosed spaces like wardrobes.5  These compounds can react in many ways to form new compounds and respirable particles, even seemingly impacting air pollution outdoors.2

Evidence

The selection of products with low or no VOC emissions is instrumental to prevent worsening in air quality. When VOCs are emitted, careful material selection in newly built spaces has been shown to accelerate VOCs reduction (i.e. off-gassing) to background levels.6 Reducing level of toxic compound emission will also help to reduce the demands of ventilation.4 Off-gassed products (e.g., reused furniture) also limit further emissions. 

Requirements

X06.1 Limit VOCs from Wet-Applied Products — 2 points

Applies to: All Spaces.

Newly installed interior wet-applied paints, coatings, adhesives, and sealants (minimum 10 distinct products or applied to at least 10% of project area) meet the following:

Verification: Letter of Assurance – Contractor

WELL Core:

Meet these requirements for the extent of developer buildout.

X06.2 Restrict VOC Emissions from Furniture, Architectural and Interior Products — 1–2 points (max 2)

Applies to: All Spaces.

Products within one or more categories and corresponding thresholds in Table 1 meet one of the following compliance requirements, earning points as shown in Table 2:

Table 1:

Product Category (from Appendix X1) Threshold for Compliance
Flooring 90% of cost or surface area
Furniture, millwork and fixtures 75% by cost
Insulation, ceiling and wall panels 75% by cost or surface area

Table 2:

Tier Achievement Points
1 One compliant product category 1
2 At least two compliant product categories 2

Verification: Letter of Assurance – Contractor

WELL Core:

Meet these requirements for the extent of developer buildout.

Frequently asked questions

How do you calculate the 'percentage by cost'?

The 'percentage by cost' is calculated by dividing the cost of the materials compliant with the feature requirements by the cost of all materials within the scope of the requirement.

When determining material cost, consider all of the expenses incurred in the purchase and delivering of the materials to their project location, including applicable taxes and fees. Do not include any costs involved in the installation and testing of the product once it reaches the project site (such as labor and equipment use).

Where the requirement asks for a minimum of "10% of project area", how is the area calculated?

The calculation for percentage of "project area" is based on area of rooms being (re)painted (or the product otherwise being applied) compared to the total project area. Any room (or other defined space such as a corridor) within the project that has a relevant product applied on the floors, walls and/or ceilings can have its total floor area counted towards meeting the applicable requirement.  

References

  1. U. S. Environmental Protection Agency. Volatile Organic Compounds' Impact on Indoor Air Quality. https://www.epa.gov/indoor-air-quality-iaq/volatile-organic-compounds-impact-indoor-air-quality. Published 2017. Updated November 6, 2017. Accessed January 22, 2020.
  2. Abbatt JPD, Wang C. The atmospheric chemistry of indoor environments. Environmental Science: Processes & Impacts. 2020.
  3. Chan CS, Lee SC, Chan W, et al. Characterisation of Volatile Organic Compounds at Hotels in Southern China. Indoor and Built Environment. 2011;20(4):420-429.
  4. Holøs SB, Yang A, Lind M, Thunshelle K, Schild P, Mysen M. VOC emission rates in newly built and renovated buildings, and the influence of ventilation – a review and meta-analysis. International Journal of Ventilation. 2019;18(3):153-166.
  5. Kang J, Liu J, Pei J. The indoor volatile organic compound (VOC) characteristics and source identification in a new university campus in Tianjin, China. Journal of the Air & Waste Management Association. 2017;67(6):725-737.
  6. Suzuki N, Nakaoka H, Nakayama Y, et al. Changes in the concentration of volatile organic compounds and aldehydes in newly constructed houses over time. International Journal of Environmental Science and Technology. 2020;17(1):333-342.
  7. California Air Resources Board. California Air Resources Board (CARB) Suggested Control Measure for Architectural Coatings In. Vol CARB SCM 20192019.
  8. U.S. Green Building Council. LEED BD+C: New Construction | v4.1 - LEED v4.1 Low-Emitting Materials. https://www.usgbc.org/credits/new-construction-core-and-shell-schools-new-construction-retail-new-construction-healthc-178. Published 2018. Accessed June 1, 2020.
  9. AgBB. Evaluation procedure for VOC emissions from building products. Part 3: LCI Values. In:2018.
  10. European Commission. EU-LCI Values.  Published 2019. Accessed January 27, 2020.