WELL v2, Q2 2025 — this page reflects the WELL v2, Q2 2025 addenda of the WELL Building Standard.

Official source: https://v2.wellcertified.com/en/wellv2/materials/feature/5

X05 Enhanced Material Restrictions (WELL v2, Q2 2025)

Concept: Materials · Type: Optimization · Maximum points: 2

Intent

Minimize the exposure to certain chemicals by limiting their presence in products.

Summary

This WELL feature requires restricting chemicals found in products commonly installed in buildings.

Issue

The materials industry has been able to develop and adapt products to satisfy the needs of the market. However, some newly introduced chemicals that pose to be advantageous from a performance or cost perspective, may be associated with negative health effects. Populations that prove to be the most vulnerable to these chemicals are unborn and young children, as well as pregnant women.1,2 Chemical classes with compounds suspected or proven to pose health concerns include orthophthalates (common plasticizers), halogenated flame retardants (HFR)1,3 and other per-fluorinated compounds (PFCs) and heavy metals, in addition to formaldehyde.4 Common pathways of exposure to these compounds are through inhalation, skin contact or swallowing of dusts, soils or larger particles. Overall, there is a great research gap in assessing the safety of these and many other chemicals,5 driven both by their ubiquity in the environment, as well as their presence in the human body. For instance, Per- and polyfluoroalkyl substances (PFAS) such as perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) are persisting PFCs in natural environments (including sources of drinking water) and found in humans.6 Metabolites of orthophthalates are partially metabolized by the body and commonly found in urine.7

Evidence

Selecting products that are devoid of or have reduced amount of chemicals associated with health concerns may help to prevent exposure to these compounds. Some organizations have published regulations, guidelines or certifications that restrict or minimize the presence of certain chemicals from these classes.

Requirements

X05.1 Select Compliant Interior Furnishings — 1 point

Applies to: All Spaces.

Meet all of the following options:

Option 1: Furniture, millwork and fixtures

At least 50% by cost of newly installed furniture, millwork and fixtures (minimum 10 distinct products), as defined in Appendix X1, meet one of the following requirements:

Verification: Technical Document (Audited), Letter of Assurance – Designer

Technical Document: Product specification sheets for 10 distinct applicable products installed in the project. If more than 10 distinct products are installed, additional specification sheets are not required.

Option 2: Electrical and electronic products

All newly installed electrical and electronic products, as specified in Appendix X1, meet the following requirement:

Verification: Technical Document (Audited), Letter of Assurance – Contractor

Technical Document: Product specification sheets for 10 distinct applicable products installed in the project (If more than 10 distinct products are installed, additional specification sheets are not required) OR a narrative that identifies applicable laws that prohibit the sale of non-compliant products.

WELL Core:

Meet these requirements for the extent of developer buildout.

X05.2 Select Compliant Architectural and Interior Products — 1 point

Applies to: All Spaces.

At least 50% by cost of newly installed products under the classes listed below, as defined by Appendix X1 (minimum 10 distinct products), meet the following requirements, unless higher amounts are mandated by local code:

Verification: Technical Document (Audited), Letter of Assurance – Contractor

Technical Document: Product specification sheets for 10 distinct applicable products installed in the project. If more than 10 distinct products are installed, additional specification sheets are not required.

WELL Core:

Meet these requirements for the extent of developer buildout.

Frequently asked questions

How do you calculate the 'percentage by cost'?

The 'percentage by cost' is calculated by dividing the cost of the materials compliant with the feature requirements by the cost of all materials within the scope of the requirement.

When determining material cost, consider all of the expenses incurred in the purchase and delivering of the materials to their project location, including applicable taxes and fees. Do not include any costs involved in the installation and testing of the product once it reaches the project site (such as labor and equipment use).

If a product specification sheet does not contain the materials named in this feature, is this enough to verify the absence of a listed ingredient?

This will meet feature requirements only if the team provides evidence that the list of products is fully inclusive and that the material is not simply omitted from the list because the list lacks sufficient detail. 

If the product specification sheets do not contain sufficient detail to confirm compliance, project teams can use disclosure documentation or ecolabels. Chemical disclosure documents such as Health product declarations (HPDs) or Declare labels may be used to document absence of chemicals as they list product ingredients to a determined level or resolution (1000 or 100 ppm). In addition, many products are certified to be free of toxicants by an ecolabel. Project teams may research in the ecolabel's acceptance criteria whether their certified products are free of certain chemicals. Ecolabels usually provide a database of certified products or their products are listed in many specialized databases. Many ecolabels are part of the Global Ecolabeling Network  (GEN, https://globalecolabelling.net/).

References

  1. Roze E, Meijer L, Bakker A, Van Braeckel Koenraad NJA, Sauer Pieter JJ, Bos Arend F. Prenatal Exposure to Organohalogens, Including Brominated Flame Retardants, Influences Motor, Cognitive, and Behavioral Performance at School Age. Environmental Health Perspectives. 2009;117(12):1953-1958.
  2. Tsuda S. Differential toxicity between perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA). The Journal of Toxicological Sciences. 2016;41(Special):SP27-SP36.
  3. Eriksson P, Jakobsson E, Fredriksson A. Brominated flame retardants: a novel class of developmental neurotoxicants in our environment? Environmental Health Perspectives. 2001;109(9):903-908.
  4. Nielsen GD, Larsen ST, Wolkoff P. Re-evaluation of the WHO (2010) formaldehyde indoor air quality guideline for cancer risk assessment. Archives of Toxicology. 2017;91(1):35-61.
  5. Wilson Michael P, Schwarzman Megan R. Toward a New U.S. Chemicals Policy: Rebuilding the Foundation to Advance New Science, Green Chemistry, and Environmental Health. Environmental Health Perspectives. 2009;117(8):1202-1209.
  6. Genuis SJ, Birkholz D, Ralitsch M, Thibault N. Human detoxification of perfluorinated compounds. Public Health. 2010;124(7):367-375.
  7. Hammel SC, Levasseur JL, Hoffman K, et al. Children's exposure to phthalates and non-phthalate plasticizers in the home: The TESIE study. Environment International. 2019;132:105061.