WELL v2, Q2 2025 — this page reflects the WELL v2, Q2 2025 addenda of the WELL Building Standard.

Official source: https://v2.wellcertified.com/en/wellv2/light/feature/1

L01 Light Exposure (WELL v2, Q2 2025)

Concept: Light · Type: Precondition

Intent

Provide indoor light exposure through daylight and electric light strategies.

Summary

This WELL feature requires projects to provide appropriate light exposure in indoor environments through lighting strategies.  

Issue

Mammals function on an approximately 24-hour cycle, following what are referred to as circadian rhythms.1 Light is the main driver of the circadian system, which controls body processes, such as digestion, the release of certain hormones, body temperature and sleep. Humans evolved their sleep schedules to be dependent on the natural day- night cycle. Electric light has only been widely used as a source of light for less than 200 years.2 The increase in the use of electric lighting has led to indoor environments relying on electric light over daylight. However, reduced exposure to light has been linked to the onset of depression and impairment of cognitive function in individuals.3,4 Irregular sleep-wake cycles have been linked to poorer academic performance in college students.5 Studies have shown that light exposure during daytime has been linked to increases in productivity and sleep quality, as well as reduction in symptoms of depression in individuals.6-8

Evidence

Providing indoor access to adequate light can positively influence the productivity and mood of individuals, while supporting the alignment of their circadian rhythms with the natural day-night cycle.9–12 Access to appropriate levels of light in indoor environments can be achieved through building design, façade design, space layout and lighting design. Windows, atriums and skylights are design features that can be utilized to increase daylight in a space. The interior layout of the space also has an impact on the daylight exposure received by users. For example, conference rooms can be added to the center of the floor plate, so that workstations can be situated near windows and have daylight exposure. Lighting strategies using electric lighting can be utilized to achieve required light exposure, when appropriate daylight exposure is not available.

Requirements

L01.1 Provide Indoor Light — Precondition

Applies to: All Spaces; excluding Dwelling Units, Guest Rooms.

Meet any one of the following options:

Option 1: Daylight simulation

The project demonstrates, through computer simulations, that one of the following conditions are achieved:

Verification: Technical Document (Audited)

Modeling report

Option 2: Interior layout

One of the following requirements is met:

Verification: Technical Document (Audited)

Architectural drawings

Option 3: Building design

One of the following requirements is met:

Verification: Technical Document (Audited)

Architectural drawings

Option 4: Circadian lighting design

The following requirement is met:

Refer to the Performance Verification Guidebook for information on sensor/testing requirements, required testing duration and compliance calculations.

Verification: Performance Test

Applies to: Dwelling Units, Guest Rooms.

Meet any one of the following options:

Option 1: Daylight simulation

The project demonstrates, through computer simulations, that the following requirement is achieved:

Verification: Technical Document (Audited)

Modeling report

Option 2: Facade design

The following requirement is met:

Verification: Technical Document (Audited)

Architectural drawings

Option 3: Circadian lighting design

The following requirement is met:

Verification: Performance Test

WELL Core:

Meet these requirements in the whole building. Projects pursuing Feature L03, Option 4 to achieve this feature are required to have access to at least 10% of leased spaces for testing (identified by the project). Projects pursuing daylighting options are required to meet the requirements in each floor or for each tenant, whichever is smaller. If finishes have not finalized, projects may use the following default surface reflectances:

If the layout of leased spaces is not yet known, the entire leased space is to be considered regularly occupied.

Frequently asked questions

Can a project team apply different options within L01 across different floors of the project?

Yes, a project team can use different options for different floors by submitting an Alternative Adherence Path (AAP) specifying which option is being used for which floor.

If a team would like to use different options and one of the options that will be pursued is Option 4: Circadian lighting design, the team will need to conduct performance testing for the floor(s) using Option 4. If the team is already targeting Feature L03, no separate performance tests are required to meet Option 4 of Feature L01. Option 4 cannot be applied to a floor with no workstations.

Can a combination of spaces be used to meet the common area seating requirements, or does a single space need to contain the seating?

Yes, a combination of spaces is acceptable, so long as combined they can seat 15% of regular occupants and each space is accessible to all occupants. 

When calculating sDA and ASE in daylight modeling, can you clarify if the interior and exterior shades/blinds can be modeled for analysis?

The exterior shades/blinds should be modeled for analysis in accordance with IES LM-83 which defines the calculation of Spatial Daylight Autonomy (sDA) and Annual Sunlight Exposure (ASE). 

Interior glare control (shades/blinds) should not be used for the ASE analysis, per the methodology outlined in IES LM-83, Section 3.2.6, but are allowed for the sDA analysis.

References

  1. Czeisler CA, Gooley JJ. Sleep and circadian rhythms in humans. Cold Spring Harb Symp Quant Biol. 2007;72:579-597. doi:10.1101/sqb.2007.72.064
  2. U.S. Department of Energy. The History of the Light Bulb. https://www.energy.gov/articles/history-light-bulb. Published 2013. Accessed April 1, 2018.
  3. Kent ST, McClure LA, Crosson WL, Arnett DK, Wadley VG, Sathiakumar N. Effect of sunlight exposure on cognitive function among depressed and non-depressed participants: A REGARDS cross-sectional study. Environ Heal A Glob Access Sci Source. 2009;8(1):34. doi:10.1186/1476-069X-8-34
  4. Ruger M. Time-of-day-dependent effects of bright light exposure on human psychophysiology: comparison of daytime and nighttime exposure. AJP Regul Integr Comp Physiol. 2005;290(5):R1413-R1420. doi:10.1152/ajpregu.00121.2005
  5. Phillips AJK, Clerx WM, O’Brien CS, et al. Irregular sleep/wake patterns are associated with poorer academic performance and delayed circadian and sleep/wake timing. Sci Rep. 2017;7(1):3216. doi:10.1038/s41598-017-03171-4
  6. Lam RW, Levitt AJ, Levitan RD, et al. Efficacy of bright light treatment, fluoxetine, and the combination in patients with nonseasonal major depressive disorder a randomized clinical trial. JAMA Psychiatry. 2016;73(1):56-63. doi:10.1001/jamapsychiatry.2015.2235
  7. Figueiro MG, Steverson B, Heerwagen J, et al. The impact of daytime light exposures on sleep and mood in office workers. Sleep Heal. 2017;3(3):204-215. doi:10.1016/j.sleh.2017.03.005
  8. Boubekri M, Cheung IN, Reid KJ, Wang CH, Zee PC. Impact of windows and daylight exposure on overall health and sleep quality of office workers: A case-control pilot study. J Clin Sleep Med. 2014;10(6):603-611. doi:10.5664/jcsm.3780
  9. Phipps-Nelson J, Redman JR, Dijk DJ, Rajaratnam SMW. Daytime exposure to bright light, as compared to dim light, decreases sleepiness and improves psychomotor vigilance performance. Sleep. 2003;26(6):695-700. doi:10.1093/sleep/26.6.695
  10. Legates TA, Fernandez DC, Hattar S. Light as a central modulator of circadian rhythms, sleep and affect. Nat Rev Neurosci. 2014;15(7):443-454. doi:10.1038/nrn3743
  11. Edwards L, Torcellini P. A Literature Review of the Effects of Natural Light on Building Occupants A Literature Review of the Effects of Natural Light on Building Occupants. Contract. 2002;(July). doi:10.2172/15000841
  12. Galasiu AD, Veitch JA. Occupant preferences and satisfaction with the luminous environment and control systems in daylit offices: a literature review. Energy Build. 2006;38(7):728-742. doi:10.1016/j.enbuild.2006.03.001
  13. Illuminating Engineering Society. 2023. IES LM-83-23: Approved Method IES Spatial Daylight Autonomy (sDA) and Annual Sunlight Exposure (ASE). https://store.ies.org/product/approved-method-ies-spatial-daylight-autonomy-sda-and-annual-sunlight-exposure-ase/?v=0b3b97fa6688