WELL v2, Q2 2025 — this page reflects the WELL v2, Q2 2025 addenda of the WELL Building Standard.

Official source: https://v2.wellcertified.com/en/wellv2/water/feature/9

W09 β Onsite Non-Potable Water Reuse (WELL v2, Q2 2025)

Concept: Water · Type: Optimization · Maximum points: 2

Intent

Conserve water through non-potable water systems without compromising the health of the building occupants.

Summary

This WELL feature requires projects to implement a safety plan when capturing and using non-potable water within the project boundary.

Issue

Efficient water management is an ever-growing need for supporting and sustaining human existence.1 The rise of extreme droughts and subsequent long-term water scarcity are requiring changes in how humans think about and use water.1 Conversely, severe rain events can overload wastewater treatment plants with storm- and rainwater, potentially resulting in combined sewer overflows (CSOs), in which untreated water is released to natural bodies of water and beaches downstream.2

Buildings can reduce the pressure on city-wide water infrastructure by supporting efficient allocation of resources, such as minimizing the use of municipally sourced water for applications that do not require potability (e.g., irrigation, flushing toilets).2 However, without proper design and operations management, there is a risk of contamination of potable water lines or oral or respiratory exposure to non-potable water.2-6

Evidence

The design and operations of a healthy, non-potable water system must address the water sources and uses. For instance, water coming from clothes washers and showers, as well as stormwater collected at the street level, requires treatment and water quality monitoring before reuse. The system should be designed so that water capture and reuse does not create niches of water stagnation, and storage tanks for non-potable water need periodic checks and safeguards against overflows.5 Additionally, pipes destined to distribute non-potable water must not be commingled with those for drinking water, and proper control measures must be in place if potable water supplements non-potable water applications (e.g., toilet flushing).2 Finally, smells and odors need to be managed to avoid the perception of a health threat, as this may hinder efforts to improve water management and conservation in a building.7, 8

While there are many factors to consider, these challenges can be managed through a properly implemented safety plan that addresses health endpoints in the collection, treatment and distribution of non-potable water within the building.9 The success in the implementation of this plan also depends on third party verification, in which the plan is evaluated with respect to the achievement of its health endpoints.10  Additionally, education and signage are essential in supporting occupants' understanding of the positive impact of sensible water utilization within buildings and of the measures taken to protect human health.11

By properly managing and controlling non-potable water reuse and capture systems, projects can help maintain occupant health and safety, while contributing to decreased water use by up to 75% in new buildings.12

Requirements

W09.1 Implement Safety Plan for Non-Potable Water Capture and Reuse — 2 points

Applies to: All Spaces.

Meet all of the following options:

Option 1: Safety plan description

The project or organization implements a safety plan that contains the following:5-9

Verification: Professional Narrative, Beta Feature Feedback Form

Option 2: Safety plan implementation

Documentation of the following are submitted annually through the WELL digital platform:

Verification: On-going Maintenance Report

Option 3: Safety plan communications

Conspicuous signage is present to communicate the following:

Verification: On-site Photographs

Photographs should showcase:
1) The color coded pipes distinguishing the non-potable water network.
2) The signage distinguishing potable fom non-potable water and, as applicable, relevant language translated to English. 
3) The informative display(s) regarding safety features and conservation goals of the non-potable system and, as applicable, relevant language translated to English.

Quantity: At least one photograph of color coded pipes, at least one photograph of non-potable water signage and at least one photograph of an informative display.

Projects are not required to provide information on the individuals assigned to perform the key roles determined in the safety plan.

This feature is a beta strategy and has an additional documentation requirement (beta feature feedback form). The feedback form supports IWBI in developing new features that are effective and applicable to projects around the world.

WELL Core:

Meet these requirements for the extent of developer buildout.

References

  1. City of Cape Town, Cape Town Water Strategy - our shared water future.
  2. Sharvelle, S. A., N.; Clerico, E.; Hultquist, R.; Leverenz, H.; and A. Olivieri. Risk-Based Framework for the Development of Public Health Guidance for Decentralized Non-Potable Water Systems; Prepared by the National Water Research Institute for the Water Environment & Reuse Foundation.: Alexandria, VA, 2017.
  3. BIO by Deloitte Optimising water reuse in the EU – Final report prepared for the European Commission (DG ENV), Part I. In collaboration with ICF and Cranfield University.; 2015.
  4. Hernández, F.; Urkiaga, A.; De las Fuentes, L.; Bis, B.; Chiru, E.; Balazs, B.; Wintgens, T., Feasibility studies for water reuse projects: an economical approach. Desalination 2006, 187, (1), 253-261.
  5. San Francisco Department of Public Health, Director’s Rules and Regulations Regarding the Operation of Alternate Water Source Systems. In Health, S. F. D. o. P., Ed. San Francisco, CA, 2017.
  6. Hamilton, K. A.; Hamilton, M. T.; Johnson, W.; Jjemba, P.; Bukhari, Z.; LeChevallier, M.; Haas, C. N., Health risks from exposure to Legionella in reclaimed water aerosols: Toilet flushing, spray irrigation, and cooling towers. Water Research 2018, 134, 261-279.
  7. BIO Intelligence Service Water Performance of Buildings, Final Report prepared for European Commission, DG Environment; 2012.
  8. Oesterholt, F.; Martijnse, G.; Medema, G.; van der Kooij, D., Health risk assessment of non-potable domestic water supplies in the Netherlands. Journal of Water Supply: Research and Technology-Aqua 2007, 56, (3), 171-179.
  9. Goodwin, D.; Raffin, M.; Jeffrey, P.; Smith, H. M., Applying the water safety plan to water reuse: towards a conceptual risk management framework. Environmental Science: Water Research & Technology 2015, 1, (5), 709-722.
  10. Natural Resource Management Ministerial Council; Environment Protection and Heritage Council; Australian Health Ministers’ Conference, National Guidelines for Water Recycling: Managing Health and Environmental Risks. In Canberra, Australia, 2006.
  11. Frijns, J.; Smith, M. H.; Brouwer, S.; Garnett, K.; Elelman, R.; Jeffrey, P., How Governance Regimes Shape the Implementation of Water Reuse Schemes. Water 2016, 8, (12).
  12. City and County of San Francisco. On-site Non-potable Water Use: Guide for the collection, treatment, and reuse of alternate water supplies in San Francisco. https://www.sfwater.org/modules/showdocument.aspx?documentid=3126