WELL v2, Q2 2025 — this page reflects the WELL v2, Q2 2025 addenda of the WELL Building Standard.

Official source: https://v2.wellcertified.com/en/wellv2/sound/feature/1

S01 Sound Mapping (WELL v2, Q2 2025)

Concept: Sound · Type: Precondition

Intent

Incorporate strategic planning required to prevent issues of acoustic disturbance from various sources of noise.

Summary

This WELL feature requires projects to strategize an acoustical plan that identifies sources of noise that can negatively impact interior spaces.

Issue

Architectural trends, such as open workspaces, lightweight construction and exposed finishes or HVAC foster acoustically uncomfortable environments.1–4 When noise from internal or external sources is increased in a space, occupants have been found to be easily distracted, less productive and susceptible to burnout.5–9 In office environments, employees care about privacy and collaboration.8,10 In one study from the United Kingdom, 99% of employees reported that their concentration was impaired by poor acoustical comfort in the workplace.7 Similar conditions are reported in workplaces worldwide.5,8,11–13 Some reports have shown that occupants are less likely to help others under high noise conditions, reducing collaboration in the workplace.6

Evidence

To address noise, floor plans should be designed with intent and use in mind.14 For example, a typical office can be categorized into four key types of programming: spaces for concentration, collaboration, socialization and learning.15 Location is important, since noise from social or collaborative spaces impacts spaces intended for concentration or learning.15,16  This approach can be implemented in any space type that incorporates spaces of socialization and recreation alongside areas for task-centric work or learning.15 These spaces can then be described as loud, quiet and mixed spaces to better assess the impact of sound on sensitive, quiet locations for concentration, learning or recreation.

Requirements

S01.1 Label Acoustic Zones — Precondition

Applies to: All Spaces.

The project provides the following:

Verification: Technical Document (Audited)

Architectural drawings

WELL Core:

Meet these requirements in the whole building, based on any knowledge of anticipated uses.

S01.2 Provide Acoustic Design Plan — Precondition

Applies to: All Spaces.

The project provides one of the following:

Verification: Professional Narrative

WELL Core:

Meet these requirements in the whole building, based on any knowledge of anticipated uses.

References

  1. Park SH, Lee PJ, Yang KS, Kim KW. Relationships between non-acoustic factors and subjective reactions to floor impact noise in apartment buildings. J Acoust Soc Am. 2016;139(3):1158-1167. doi:10.1121/1.4944034
  2. Oseland N. Psychoacoustics Survey Results. 2015;(September):1-32. http://workplaceunlimited.com/Psychoacoustics Final Report.pdf.
  3. Oseland N, Hodsman P. Psychoacoustics Resolving Noise Distractions in the Workplace. In: Hedge A, ed. Ergonomic Workplace Design for Health, Wellness, and Productivity. 1st ed. Routledge; 2016:73-101. https://www.ingentaconnect.com/content/rout/2fbfgk/2017/00000001/00000001/art00005.
  4. Hodsman P. Planning for Psychoacoustics: A Psychological Approach to Resolving Office Noise Distraction. 2015.
  5. Kaarlela-Tuomaala A, Helenius R, Keskinen E, Hongisto V. Effects of acoustic environment on work in private office rooms and open-plan offices - Longitudinal study during relocation. Ergonomics. 2009;52(11):1423-1444. doi:10.1080/00140130903154579
  6. Kim J, de Dear R. Workspace satisfaction: The privacy-communication trade-off inopen-plan offices. J Environ Psychol. 2013;36:18-26. doi:10.1016/j.jenvp.2013.06.007
  7. Banbury SP, Berry DC. Office noise and employee concentration: Identifying causes of disruption and potential improvements. Ergonomics. 2005;48(1):25-37. doi:10.1080/00140130412331311390
  8. Hedge A. The open-plan office: A Systematic Investigation of Employee Reactions to Their Work Environment. Environ Behav. 1982;14(5):519-542. doi:10.1177/0013916582145002
  9. Brammer A, Laroche C. Noise and communication: A three-year update. Noise Heal. 2012;14(61):281. doi:10.4103/1463-1741.104894
  10. Sailer U, Hassenzahl M. Assessing noise annoyance: An improvement-oriented approach. Ergonomics. 2000;43(11):1920-1938. doi:10.1080/00140130050174545
  11. Navai M, Veitch J a. Acoustic Satisfaction in Open-Plan Offices: Review and Recommendations. 2003:23. doi:http://doi.org/10.4224/20386513
  12. Frontczak M, Schiavon S, Goins J, Arens E, Zhang H, Wargocki P. Quantitative relationships between occupant satisfaction and satisfaction aspects of indoor environmental quality and building design. Indoor Air. 2012;22(2):119-131. doi:10.1111/j.1600-0668.2011.00745.x
  13. Keus van de Poll M, Carlsson J, Marsh JE, et al. Unmasking the effects of masking on performance: The potential of multiple-voice masking in the office environment. J Acoust Soc Am. 2015;138(2):807-816. doi:10.1121/1.4926904
  14. General Services Administration, Service PB. PBS-P100 Facilities Standards for the Public Buildings Service. 2016;(March):333. doi:10.1017/CBO9781107415324.004
  15. Gensler. What we’ve learned about focus in the workplace. 2012. https://www.gensler.com/uploads/document/306/file/Focus_in_the_Workplace_10_01_2012.pdf.
  16. Moeller N. Placing Sound Masking on the Front Line of Acoustic Design. Construction Canada. https://www.constructioncanada.net/placing-sound-masking-on-the-front-line-of-acoustic-design/. Published 2017. Accessed April 1, 2018.