WELL v2, Q2 2025 — this page reflects the WELL v2, Q2 2025 addenda of the WELL Building Standard.

Official source: https://v2.wellcertified.com/en/wellv2/materials/feature/1

X01 Material Restrictions (WELL v2, Q2 2025)

Concept: Materials · Type: Precondition

Intent

To reduce or eliminate human exposure to building materials known to be hazardous.

Summary

This WELL feature restricts widely known hazardous ingredients in newly installed building materials, specifically asbestos, mercury and lead.

Issue

Historical use of hazardous materials in construction, specifically asbestos, mercury and lead, have presented serious and negative health impacts on humans. Disease caused by exposure to these chemicals, including asbestosis, developmental issues in children1 and various forms of cancer still affect millions of people.2 While these compounds have been restricted or banned in buildings in many countries, they still pose threats in countries that have not enacted the necessary limitations. As a result, exposure to these hazardous materials should be limited and, if possible, eliminated.

Evidence

Asbestos has been fully or partially banned for buildings in most countries and alternatives are widely available. Lead content in materials that may expose humans to its aspiration and ingestion is also restricted in many national regulations.3 Use of products where lead content is minimized or not added can significantly reduce leaching from pipes into drinking water. Eliminating the use of compact fluorescent light bulbs (CFLs) removes a potential pathway for exposure to mercury.

Requirements

X01.1 Restrict Asbestos — Precondition

Applies to: All Spaces.

For newly installed or applied products within the project boundary, the following requirement is met:

Verification: Technical Document (Audited), Letter of Assurance – Contractor

Technical Document: Product specifications sheets for each distinct applicable product installed in the project (up to a maximum of 20) OR a narrative that identifies applicable laws that prohibit the sale and use of asbestos-containing materials in buildings.

WELL Core:

Meet these requirements for the extent of developer buildout.

X01.2 Restrict Mercury — Precondition

Applies to: All Spaces.

The following requirements are met:

Verification: Technical Document (Audited), Letter of Assurance – Designer

Technical Document: Product specification sheets for each distinct applicable product installed in the project (up to a maximum of 10) OR a narrative that identifies applicable laws that prohibit the sale of products not compliant with RoHS restrictions.

WELL Core:

Meet these requirements for the extent of developer buildout.

X01.3 Restrict Lead — Precondition

Applies to: All Spaces.

Meet all of the following options:

Option 1: Paints and electronics

The following requirements are met:

Verification: Technical Document (Audited), Letter of Assurance – Contractor

Technical Document: Product specification sheets for each distinct applicable product installed in the project (up to a maximum of 10) OR a narrative that identifies applicable laws that prohibit the sale of non-compliant products.

Option 2: Drinking water pipes, fittings and solder

Pipes, fixtures, fittings and solder newly installed or applied within the project boundary intended for drinking water distribution and delivery meet at least one of the following:

Verification: Letter of Assurance – Engineer

WELL Core:

Meet these requirements for the extent of developer buildout.

Frequently asked questions

If a product specification sheet does not contain the materials named in this feature, is this enough to verify the absence of a listed ingredient?

This will meet feature requirements only if the team provides evidence that the list of products is fully inclusive and that the material is not simply omitted from the list because the list lacks sufficient detail. 

If the product specification sheets do not contain sufficient detail to confirm compliance, project teams can use disclosure documentation or ecolabels. Chemical disclosure documents such as Health product declarations (HPDs) or Declare labels may be used to document absence of chemicals as they list product ingredients to a determined level or resolution (1000 or 100 ppm). In addition, many products are certified to be free of toxicants by an ecolabel. Project teams may research in the ecolabel's acceptance criteria whether their certified products are free of certain chemicals. Ecolabels usually provide a database of certified products or their products are listed in many specialized databases. Many ecolabels are part of the Global Ecolabeling Network  (GEN, https://globalecolabelling.net/).

References

  1. Agency for Toxic Substances Disease Registry. Toxicological Profile for Lead. https://www.atsdr.cdc.gov/toxprofiles/tp.asp?id=96&tid=22. Published 2007. Accessed January 2, 2020.
  2. Furuya S, Chimed-Ochir O, Takahashi K, David A, Takala J. Global Asbestos Disaster. International Journal of Environmental Research and Public Health. 2018;15(5).
  3. UN Environment Programme. Update on the Global Status of Legal Limits on Lead in Paint, September 2018. 2018.
  4. European Parliament and the Council of the European Union. Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment. In. Vol 2011/65/EU Latest consolidated version: 22/07/2019 ed: Official Journal of the European Union; 2011.
  5. U.S. Green Building Council. LEED BD+C: Healthcare | v4.1 - LEED v4.1 PBT source reduction - mercury. USGBC. https://www.usgbc.org/node/12022740. Published 2019. Accessed Accessed on December 19, 2019, 2019.