WELL v2, Q2 2025 — this page reflects the WELL v2, Q2 2025 addenda of the WELL Building Standard.

Official source: https://v2.wellcertified.com/en/wellv2/appendix/t1

Appendix T1 — Thermal Comfort (WELL v2, Q2 2025)

Surveys may be administered via paper-based surveys distributed to occupants or through a digital survey such as a website or mobile application. It is recommended that surveys are administered during mid-morning or mid-afternoon, at least 30 minutes after arrival or after a lunch break. 

Survey Questionnaire:

Please answer the following questions regarding your general thermal experience during the current heating/cooling season.

1. Please rate your satisfaction level with the thermal environment in this space:

    □ Very Dissatisfied

    □ Dissatisfied

    □ Slightly Dissatisfied

    □ Neutral

    □ Slightly Satisfied

    □ Satisfied

    □ Very Satisfied

2. Would you prefer this area to be:

    □ Cooler

    □ Slightly Cooler

    □ No Change Required

    □ Slightly Warmer

    □ Warmer

If your answer to Question 1 contains the word “Dissatisfied,” please answer the following two questions:

3. How do you generally perceive the thermal environment in this area:

    □ Cold

    □ Cool

    □ Slightly Cool

    □ Neutral

    □ Slightly Warm

    □ Warm

    □ Hot

4. Please mark the potential source (or sources) of your thermal discomfort:

    □ Inappropriate room thermostat setpoint temperature

    □ Thermostat setpoint temperature being adjusted by occupants

    □ Daily variations in room temperature (such as higher temperature in the afternoons)

    □ Occasional variations in room temperature (such as being occasionally warm or cold)

    □ Parts of the room being too hot

    □ Parts of the room being too cold

    □ Humidity level is too high

    □ Dry air

    □ Air movement is too high

    □ Air movement is too low

    □ Hot/cold air coming from windows

    □ Hot/cold walls

    □ Solar radiation

    □ Local thermal discomfort (part/parts of the body being cold or hot)

    □ Heat from equipment and appliances

    □ Strict dress code

    □ Hot/cold furniture surfaces

    □ Furniture causing hot/cold thermal discomfort or sweating

    □ Others                                                                      

Example of Result Analysis:

The Percentage of Satisfaction should be reported as the percentage of people who are satisfied with the thermal environment of the space as shown in the following equation:

Percentage of Satisfaction = (Number of Satisfied Occupants)/(Number of Surveyed Occupants)∙100

Occupants voting for “Neutral,” “Slightly Satisfied,” “Satisfied,” and “Very Satisfied” should be deemed satisfied with the room's thermal environment. Table 1 shows the results from a typical survey and Table 2 depicts a simple example of the survey report. The results of question 2 (and question 3 if applicable) should be submitted as the number of votes for each thermal sensation and preferences condition as specified in Table 2.

Table 1: Results from a Typical Thermal Comfort Satisfaction Survey with 15 Participants

  Question 1 Question 2 Question 3 Question 4
Subject 1 Very Satisfied No Change    
Subject 2 Satisfied Slightly Cooler    
Subject 3 Slightly Dissatisfied   

Warmer

Cold    Parts of the room being too cold 
Subject 4

Slightly Dissatisfied

Slightly Warmer Cool  Hot/Cold air coming from windows
Subject 5 Satisfied No Change    
Subject 6 Very Satisfied No Change    
Subject 7 Neutral  Slightly Warmer    
Subject 8 Very Satisfied No Change    
Subject 9 Dissatisfied  Warmer Slightly Cool 

Inappropriate room thermostat setpoint temperature 

Subject 10 Slightly Satisfied    Slightly Cooler       
Subject 11 Neutral  Slightly Warmer  Slightly Cool    Hot/Cold air coming from windows 
Subject 12 Slightly Satisfied   Slightly Warmer       
Subject 13 Very Satisfied No Change     
Subject 14 Slightly Satisfied   Slightly Warmer       
Subject 15 Satisfied No Change     

Table 2: A typical Thermal Comfort Satisfaction Survey Report

1.  Please rate your satisfaction level with the temperature in this room:

Considered Dissatisfied

Considered Satisfied

Very Dissatisfied

Dissatisfied

Slightly Dissatisfied 

Neutral 

Slightly Satisfied 

Satisfied  

Very Satisfied

0

1

2

2

3

3

4

Percentage of Occupant Satisfaction:

80%

2.  Would you prefer this area to be (based on the number of votes):

Cooler

Slightly Cooler

No Change

Slightly Warmer

Warmer

0

2

6

5

2

3.  How do you generally perceive the thermal environment in this area (based on the number of votes): 

Cold

Cool

Slightly Cool

Neutral

Slightly warm

Warm

Hot

1

1

2

0

0

0

0